Solar Actuator ZSA-62

Technical features

SizeZSA-62-Tr/L ZSA-62-Tr/N
Static holding force [kN] 62 62
Dynamic adjusting force [kN] 25 25
Spindle dimension Tr 44x7 Tr 44x7
Max. stroke* [mm] 1200 1200
Lifting speed [mm/s]
24V DC | 230/400V AC, 3~
1.08 | 1.02
2.23 | 1.85
End position switch 2 Limit switches 2 Limit switches
Emergency limit switch (security switch) 2 Limit switches 2 Limit switches
Reference switch 1 Limit switch at stroke middle 1 Limit switch at stroke middle
Drive mechanism Motor | Planetary gear box | Rotary encoder | Brake Motor | Planetary gear box | Rotary encoder | Brake
Operating voltage standard [V DC] 24 24
Rated power at max. adjusting force [W]** ca. 94 196
Impulse per spindle pitch 725 350
Operational voltage optional [V AC] 230/400, 3~
230/400, 3~
Rated power at max. adjusting force [W]** ca. 89 162
Impulse per spindle pitch 604 332
Connection type 2 Cables 5 m, open end 2 Cables 5 m, open end
Fitting position Optional Optional
Fitting position (to advise) Downward standing torque tube Downward standing torque tube
Accessories Pivot brackets Pivot brackets
Protection class IP 65 IP 65
Operating temperature [C°] -20 to +70 -20 to +70
Relative humidity [%] 95 95

* please note capacity diagram; higher stroke optional
** rated power at 20°C


Dimensioning


Capacity diagram ZSA-62

Document Actions